$0.00
NBRC RPFT Exam Dumps

NBRC RPFT Exam Dumps

Registry Examination for Advanced Pulmonary Function Technologists Exam

Total Questions : 111
Update Date : October 10, 2024
PDF + Test Engine
$65 $95
Test Engine
$55 $85
PDF Only
$45 $75



Last Week RPFT Exam Results

150

Customers Passed NBRC RPFT Exam

95%

Average Score In Real RPFT Exam

99%

Questions came from our RPFT dumps.



Real NBRC RPFT Dumps With 100% Passing Guarantee

Congratulations on taking the first step towards achieving the prestigious RPFT certification! At Pass4SureHub, we are committed to helping you excel in your career by providing top-notch dumps for the RPFT exam. With our comprehensive and well-crafted resources, we offer you a 100% passing guarantee, ensuring your success in the certification journey.

Why Choose Pass4SureHub for RPFT Exam Preparation?

Expertly Curated Study Guides: Our study guides are meticulously crafted by experts who possess a deep understanding of the RPFT exam objectives. These RPFT dumps cover all the essential topics.

NBRC RPFT Online Test Engine

Practice makes perfect, and our online RPFT practice mode are designed to replicate the actual test environment. With timed sessions, you'll experience the pressure of the real exam and become more confident in managing your time during the test and you can assess your knowledge and identify areas for improvement.

NBRC RPFT Detailed Explanations for Answers

Understanding your mistakes is crucial for improvement. Our practice RPFT questions answers come with detailed explanations for each question, helping you comprehend the correct approach and learn from any errors.

Dedicated Support of RPFT Exam

Our support team is here to assist you every step of the way. If you have any queries or need guidance, regarding RPFT Exam Question Answers then feel free to reach out to us. We are dedicated to your success and are committed to providing prompt and helpful responses.

Join the Community of Successful Professionals of NBRC RPFT Exam

Pass4SureHub takes pride in the countless success stories of individuals who have achieved their NBRC RPFT certification with our real exam dumps. You can be a part of this community of accomplished professionals who have unlocked new career opportunities and gained recognition in the IT industry.

Your Success is Guaranteed

With Pass4SureHub's RPFT exam study material and 100% passing guarantee, you can approach the certification exam with confidence and assurance. We are confident that our comprehensive resources, combined with your dedication and hard work, will lead you to success.


Related Exams


NBRC RPFT Sample Question Answers

NBRC RPFT Sample Questions

Question # 1

A pulmonary function laboratory routinely tests five subjects as biologic controls. Acceptable instrument performance over time is indicated when measurements

A. For each individual are within 2 standard deviations of the mean of previous measurements for each individual. 
B. For an individual are within 2 standard deviations of the mean of those for the group
C. Of the group as a whole agree with those predicted by linear regression for changes in age
D. Are within the 95% confidence interval predicted for an individual being tested. 



Question # 2

Which of the following thresholds for a clinically significant change in lung function from the beginning to the end of a methacholine challenge test is significant?

A. An increase of more than 20% in airway resistance 
B. Adecline of more than 30% in FEF25-75% 
C. Adecline of more than 20% in FEV1 
D. Adecline of more than 20% in inspiratory capacity 



Question # 3

A government agency requires that a pulmonary function technologist establish proceduresto minimize the loss of laboratory data. Which of the following should be included in theseprocedures?1. Continuous mirroring of hard drives2. Storage of duplicate test data offsite3. No Internet connections to the computer storing the database4. Contracting with a third-party security company

A. 2,3, and 4 only 
B. 1,3, and 4 only 
C. 1,2, and 4 only
D. 1,2, and 3 only 



Question # 4

While performing a quality control test on an open circuit nitrogen system, the volume of a 3-liter syringe is measured as 3.9 L. Which of the following is the most probable explanation?

A. There was an air leak in the system. 
B. The initialO2concentration in the syringe was greater than 0.21. 
C. The volume was not corrected from ATPS to BTPS.  
D. The nitrogen analyzer gain was set too low. 



Question # 5

A treadmill belt stops for a fraction of a second each time the patient takes a step. A pulmonary function technologist should

A. Instruct the patient to use the hand rails. 
B. Tighten the belt. 
C. Increase the speed of the belt. 
D. Decrease the treadmill grade. 



Question # 6

A patient is performing a flow-volume loop. A pulmonary function technologist observes equal decreases in expiratory and inspiratory flows resulting in plateaus. Patient effort is satisfactory, and he follows instructions well. The technologist should expect the patient to have a

A. Small airways obstruction 
B. Restrictive disorder
C. Variable large airways obstruction
D. Fixed large airways obstruction. 



Question # 7

A pulmonary function technologist is asked to select gas concentrations to simulate pediatric patients' exhaled concentrations during a DLcosimulation. Which of the following FECO concentrations should the technologist select?

A. 0.200 
B. 0.300 
C. 0.400 
D. 0.100 



Question # 8

Prior to an exercise study, a pulmonary function technologist finds that the patient's RER is 1.13. Which of the following bestexplains this finding?

A. Carbohydrate metabolism 
B. Protein metabolism 
C. Hypoventilation
D. Hyperventilation



Question # 9

When selecting gas tanks for a DLcosimulator, which of the following expired CO gas concentrations will produce the highest simulated DLco? 

A. 0.08 
B. 0.30
C. 0.10 
D. 0.15 



Question # 10

The desiccant column on an infrared CO2analyzer is pink. The readings obtained from this analyzer would result in

A. Adecreased CO2
B. An increased CO2
C. An unstable reading 
D. No effect on CO2 



Question # 11

A smoking cessation program using a nicotine patch is started for all smokers in a factory. Results revealed that smokers who reported they had quit had exhaled carbon monoxide levels less than 6 ppm. A pulmonary function technologist should conclude that

A. The program was effective in accomplishing smoking cessation. 
B. The smokers had refrained from smoking for the previous 6 hours. 
C. The smokers were not being truthful about smoking cessation. 
D. Adifferent method of smoking cessation should be offered to improve outcomes. 



Question # 12

A pulmonary function technologist is performing quality control on a nebulizer used in the 5- breath dosimeter bronchial challenge. The target output of the device is 0.09 mL, plus or minus 10%. After 10 actuations, the nebulizer output was 75µL with a 2.0 mL initial saline dose in the nebulizer. The technologist should 

A. Open the vent before starting the bronchial challenge. 
B. Add an exhalation filter and proceed with testing patients. 
C. Clean and reevaluate this nebulizer. 
D. Accept the results and begin using the device. 



Question # 13

A body plethysmograph box pressure transducer fails the electronic calibration check after multiple attempts. Which of the following should a pulmonary function technologist do? 1. Perform a biologic control test2. Inspect the door seal. 3. Re-zero the box pressure transducer. 4. Perform a physical pressure calibration.

A. 1,2, and 4 only 
B. 1,3, and 4 only 
C. 2,3, and 4 only 
D. 1,2, and 3 only 



Question # 14

A patient with severe airflow limitation pants too rapidly (> 3 breaths/second) against a closed shutter in a body plethysmograph. Which of the following will occur?

A. VTGunderestimation
B. VTGoverestimation  
C. RAWunderestimation 
D. RAWoverestimation 



Question # 15

Which of the following information reported from a recent methacholine challenge test best summarizes the patient's bronchial hyperresponsiveness?

A. patient reported chest tightness and a cough 
B. diluent FEV1= 92% predicted
C. postbronchodilator recovery FEV1=106% baseline 
D. PC20= 2.3 mg/mL 



Reviews From Our Customers